Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 4299, 2020 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-32152426

RESUMO

This paper presents information on the gross alpha and gross beta activity concentrations of two hundred twenty-six groundwater samples collected by gas flow proportional counters in southern Vietnam. The gross alpha results in the water samples ranged from 0.024 to 0.748 Bq L-1 with a mean of 0.183 ± 0.034 Bq L-1, and the gross beta results in the water samples ranged from 0.027-0.632 Bq L-1 with a mean of 0.152 ± 0.015 Bq L-1. The values obtained in this work were compared with those previously published for various regions or countries. Next, untreated and treated groundwater samples were analyzed to assess their influences on the treatment process. The results showed that there were differences in the minimum detection concentrations and the mean activity values between the untreated and treated groundwater samples (The p-value of the mean comparison tests is significant with p < 0.05). In both sample groups, there was a strong positive correlation of the gross alpha versus the gross beta results (r > 0.6). This means that among the radionuclides, the major sources of beta radiation are uranium and thorium decay series radionuclides. Finally, the annual effective dose for adults (>17 years) was calculated based on the assumption that major radionuclides have the highest effective dose conversion factors. In general, the results for Pb-210, Ra-226, and Ra-228 were observed to be lower than the recommended reference values established by the World Health Organization and the International Atomic Energy Agency, except for the value of Po-210.


Assuntos
Partículas alfa/efeitos adversos , Partículas beta/efeitos adversos , Água Subterrânea/análise , Saúde Pública , Exposição à Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Poluentes Radioativos da Água/análise , Água Potável/análise , Promoção da Saúde , Humanos , Doses de Radiação , Poluentes Radioativos da Água/normas
2.
J Environ Radioact ; 184-185: 109-113, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29407639

RESUMO

In this work, an advanced analytical procedure was applied to calculate radioactivity in spiked water samples in a close geometry gamma spectroscopy. It included MCNP-CP code in order to calculate the coincidence summing correction factor (CSF). The CSF results were validated by a deterministic method using ETNA code for both p-type HPGe detectors. It showed that a good agreement for both codes. Finally, the validity of the developed procedure was confirmed by a proficiency test to calculate the activities of various radionuclides. The results of the radioactivity measurement with both detectors using the advanced analytical procedure were received the ''Accepted'' statuses following the proficiency test.


Assuntos
Monitoramento de Radiação/métodos , Poluentes Radioativos/análise , Radioatividade , Meio Ambiente , Raios gama
3.
Appl Radiat Isot ; 116: 174-7, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27552123

RESUMO

In this study, a procedure to estimate thickness of the inner dead-layer of an n-type coaxial HPGe detector is described. Experimental measurements are carried out with standard point sources: (54)Mn, (57)Co, (60)Co, (88)Y, (109)Cd, (134)Cs, (137)Cs, and (152)Eu at distances of 5 and 10cm from source to detector. Shape and dimensions of a high-purity germanium (HPGe) detector are determined by radiography to characterize the geometry accurately for Monte Carlo simulation. The role of thickness of the inner dead-layer on full energy peak efficiency is illustrated by MCNP5 code, and it is observed that slope coefficient of efficiency curve has a linear relationship with thickness of the dead-layer. The adjustment of dead-layer yields good agreement, with relative deviation of ≤3%, between experimental efficiency and simulated efficiency in the energy range of 88-1836keV.

4.
J Environ Radioact ; 164: 197-201, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27500857

RESUMO

In this study, in situ gamma spectra using NaI(Tl) detector have been compared with the laboratory measurements by using HPGe detector on geological samples. The results for measuring naturally occurring terrestrial gamma radiation of 40K and the decay series of 232Th and, 238U respectively of both detectors show a maximum deviation about 5%. The mass activities series from both detectors were checked for coherence using proficiency test procedure from the International Atomic Energy Agency. The reliability and precision pass for final scores for all the analytical determinations of are received "acceptable" for all radionuclides.


Assuntos
Iodetos , Monitoramento de Radiação/métodos , Radioisótopos/análise , Sódio , Espectrometria gama , Tálio , Radioatividade , Reprodutibilidade dos Testes
5.
Appl Radiat Isot ; 109: 544-546, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26717796

RESUMO

In this work, segmented gamma scanning and the gamma emission tomography were used to locate unknown sources in a radioactive waste drum. The simulated detector response function and full energy peak efficiency are compared to corresponding experimental data and show about 5.3% difference for an energy ranging from 81keV to 1332.5keV for point sources. Computation of the corresponding activity is in good agreement with the true values.

6.
Appl Radiat Isot ; 105: 294-298, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26363240

RESUMO

This article focuses on the possible application of a (137)Cs low-radioactive source (5mCi) and a NaI(Tl) detector for measuring the saturation thickness of solid cylindrical steel targets. In order to increase the reliability of the obtained experimental results and to verify the detector response function of Compton scattering spectrum, simulation using Monte Carlo N-particle (MCNP5) code is performed. The obtained results are in good agreement with the response functions of the simulation scattering and experimental scattering spectra. On the basis of such spectra, the saturation depth of a steel cylinder is determined by experiment and simulation at about 27mm using gamma energy of 662keV ((137)Cs) at a scattering angle of 120°. This study aims at measuring the diameter of solid cylindrical objects by gamma-scattering technique.

7.
Appl Radiat Isot ; 70(9): 2112-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445105

RESUMO

The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed.


Assuntos
Algoritmos , Artefatos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/métodos , Radiometria/normas , Espectrometria gama/métodos , Meia-Vida , Internacionalidade , Doses de Radiação , Radioisótopos/química , Padrões de Referência , Valores de Referência
8.
Appl Radiat Isot ; 68(7-8): 1407-12; discussion 1412, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20117939

RESUMO

A comparison of the coincidence summing correction methods is presented. Since there are several ways for computing these corrections, each method has advantages and drawbacks that could be compared. This part of the comparison was restricted to point sources. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing correction factors for several energies of (152)Eu and (134)Cs, and three source-to-detector distances. They are presented and discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...